Installation Instructions

PT-0-1.5PSI-01, PT-0-3PSI-01, PT-0-5PSI-01, and PT-0-10PSI-01

Pressure Transducers

 

Warning-Symbol.png

WARNING – Maretron pressure transducers are not approved for use with gasoline. If you wish to use the FPM100 to monitor pressures or levels of gasoline, you must obtain a pressure transducer that is approved for use with gasoline.

Instructions

Please follow these instructions to connect any of the PT-0-1.5PSI-01, PT-0-3PSI-01, PT-0-5PSI-01, or PT-0-10PSI-01 pressure transducers to the NMEA 2000® network via a Maretron FPM100 Fluid Pressure Module. The wiring diagram appears in Figure 1 below. The diagram shows a connection to channel #0, but connections to other channels are similar.

 

1.      Please refer to the FPM100 User’s Guide for detailed information on selecting a mounting location for the pressure transducer.

 

2.      All Maretron pressure transducer assemblies are equipped with a ¼” NPT male threaded fitting. Install the pressure transducer to a ¼” NPT female fitting on the system or tank to be monitored with a maximum torque of 133 to 177 in-lbs (15 to 20 Nm). If you are monitoring a system where pressure spikes or transients will occur, or where the pressure will exceed the maximum pressure rating of the pressure transducer, install a Pressure Snubber (PT-SNUB-01) onto the system being monitored first, then install the pressure transducer to the female port on the pressure snubber.

 

3.      Connect the two wires of the pressure transducer to a free pressure monitoring channel. Connect the white wire from the pressure transducer to the positive (+) terminal of the channel and connect the brown wire from the pressure transducer to the negative (-) terminal of the channel. The example in Figure 1 shows the pressure transducer connected to switch channel 0 with the white wire connected to “P0+”, and the brown wire connected to “P0-”. Pressure transducers of “Gauge” type allow atmospheric pressure to the sensor through the connecting cable. Take care to not allow the end of the cable with the tinned wire leads to be exposed to moisture, or the sensor may become damaged due to corrosion. If the area where the end of the cable is located might have moisture present, the use of 1) a waterproof junction box with cable glands and a PTFE vent or 2) a desiccant cartridge is highly recommended. Running the cable through a cable gland will not affect its ability to allow atmospheric pressure through the cable into the sensor.

 

4.      Use a Maretron DSM Series display (firmware 1.4.7 or higher) or the DSM250 viewing function of the Maretron N2KAnalyzer® V3 software to configure the connected channel. Please refer to the FPM100 User’s Manual for configuration details.

 

5.      Supply Power to the NMEA 2000 network and verify that the pressure channel indicates a valid pressure reading.

 

Text Box: P0+Text Box: P1-Text Box: WhiteText Box: P1+Text Box: P2+Text Box: P2-Text Box: P3+Text Box: P3-Text Box: P4+Text Box: P4-Text Box: P5+Text Box: P5-Text Box: P0-Text Box: Brown

Figure 1 – Pressure Transducer Connection Diagram

 

Pressure Transducer Mechanical Drawing

 

 

Pressure Transducer Specifications

Part Number

Operating Range

Accuracy

Cable Length

PT-0-1.5PSI-01

0 to 1.5 PSI (0.10 bar)

±3% Full Scale

4.9 ft (1.5 m)

PT-0-3PSI-01

0 to 3 PSI (0.21 bar)

±2% Full Scale

4.9 ft (1.5 m)

PT-0-5PSI-01

0 to 5 PSI (0.34 bar)

±2% Full Scale

4.9 ft (1.5 m)

PT-0-10PSI-01

0 to 10 PSI (0.69 bar)

±1% Full Scale

4.9 ft (1.5 m)

 

Specification

Value

Sensor Type

Gauge

Output

4 – 20 mA current loop, loop powered

Excitation Voltage

9 VDC to 30 VDC

Compatible Fluids / Gases

Air, Brake Fluid, Diesel, Diesel Exhaust Fluid (DEF), Hydraulic Fluid, Hydrogen, Kerosene, Motor Oil, Nitrogen, Refrigerant, Fresh Water, Sea Water, and Waste Water

Operating Temperature

23°F to 140°F (-5°C to 60°C)

Media Temperature

-13°F to 257°F (-25°C to 125°C)

Over Pressure Max

29 PSI (2 bar)

Construction

1.4305 (303 Stainless Steel), Thick Film on Ceramic Al2O3 (96 %) Sensor, FKM 70 Sh O-Ring

Cable

IP67, PVC (cable gland PA6-3)

Vibration

4 g (10 – 2000 Hz)

Shock

50 g/8 ms

EMC Compatibility

EN 61000-6-3, EN 61000-6-2

Humidity

Max. 95% relative

Weight

110g

 

 

 

 